Member Since: 06/23/08
3 lifetime posts
Bvplumbing
Bob,

Weil-McClain used to make an Electric Tankless Steam boiler. My Project is that I'm replacing my oil fired combi boiler. I've got the hot water solution. Two-tankless hot water units in parallel. But, I'm having great difficulty with the Electric Steam boiler. Do you know of any suppliers with Electric Residential Steam boilers, either Tankless or the usual Electric Steam boiler. I'm looking for something in the 72 kw/ 220btu/lbs/hr range. No more Oil or Gas for me and my home.

Thanks for all your help

Carlton P.

RogerLBurkhart

03:58PM | 10/27/08
Member Since: 10/26/08
3 lifetime posts
Yes, our company, Reimers Electra Steam, Inc., manufactures electric steam boilers. Our Model RHC-72 will provide 72 KW of saturated steam for residential or commercial heating.

NOTE: These small boilers only work on two pipe systems (i.e. systems with steam traps & condensate returns). They will not work on a single pipe (Hartford Loop).

CONTACT: Roger L. Burkhart

540-662-3811 Rburkhart@reimersinc.com

Sylvan

09:41AM | 10/28/08
Member Since: 01/24/06
1507 lifetime posts
Me_office1
Hey Rodger, No Hartford loop then how does this type of boiler pass an ASME section IV inspection or NBBI even with a LWCO W? manual reset?

nalibali

04:34AM | 10/30/08
Member Since: 06/23/08
3 lifetime posts
Thanks, Roger, but I do have an One pipe system. Steam and condensate through the same pipe.

RogerLBurkhart

10:33AM | 11/03/08
Member Since: 10/26/08
3 lifetime posts
The Hartford Loop deals with the return from the system.

Small electric steam boilers utilize condensate return tanks. Each of our units meet ASME SECTION I, PARTS PMB & PEB. Our larger units meet ASME SECTION IV. All of them are inspected & registered by the National Board of Boiler Inspectors.

nalibali

06:43AM | 11/05/08
Member Since: 06/23/08
3 lifetime posts
Roger,

How does this Help me! How hard would it be to fit your unit with the Hartford Loop? I'm sure easier than me adding extra piping and radiators replacements for an seperate return. I'm still looking.

Thanks

RogerLBurkhart

10:04AM | 11/05/08
Member Since: 10/26/08
3 lifetime posts
This will not assist you. Electric boilers are not suitable for one pipe systems.

Roger
Click_to_reply_button Inspiration_banner

INSPIRATION GALLERY



Post a reply as Anonymous

Photo must be in JPG, GIF or PNG format and less than 5MB.

Reply_choose_button

captcha
type the code from the image

Anonymous

Post_new_button or Login_button
Register

Follow_banner_a
Newsletter_icon Google_plus Facebook Twitter Pinterest Youtube Rss_icon
 
webapp2