I have a relatively new house (>2 yrs) with a head-scratcher. When I run water continuously at one side of the dual vanity for more than a couple of minutes, I hear a "popping" sound behind the mirror and - it seems - overhead. It starts slowly and frequency of pops increases to about every 3 seconds or so. It seems to be worse during colder weather. It is a second floor bath with attic/mechanicals directly above.

It is only the one side; also have a shower, garden tub, and toilet in this bathroom with no funny sounds. It also happens with hot or cold water. A friend suggested the drain vent, but not an actual problem or solution. Thanks for any help.

LarryG

03:54PM | 04/01/10
Member Since: 07/22/04
531 lifetime posts
i think the noise is originating from the faucet and not the drain.

doesn't the vanity share a common discharge pipe?

Sylvan

10:52AM | 04/02/10
Member Since: 01/24/06
1581 lifetime posts
Me_office1
If your using the hot water side of the faucet as the hot water moves through the piping it expands and this could very easily cause sounds of expansion and contraction.

vents have air thus no "poping" will be heard Also like Larry said it could be a faucet lose washer causing sounds

clee1138

10:46AM | 04/03/10
Member Since: 03/30/10
2 lifetime posts
Thanks to both of you for the replies. I originally thought it was the hot water line too and that the pipe was expanding/contracting until I started trying different combinations throughout the bathroom to narrow it down. It also does it the cold water running, though. My hot water heater is in the attic maybe 25 feet from the sink, but my supply line runs down the outer wall of the house to the crawlspace and back up to the other floors (seems wasteful to me). We theorized the vent problem since I hear the noise overhead. Could a fixture problem sound like it's overhead with the mirror acting like a sound dampener? Just another theory...

LarryG

02:03PM | 04/03/10
Member Since: 07/22/04
531 lifetime posts
it only does it on the one side?

try removing the aerator from the tip of the faucet and flush the lines out for a couple minutes and see if anything changes.

doug seibert

05:01PM | 04/03/10
Member Since: 08/10/02
842 lifetime posts
PVC has a high Coefficient Of Expansion..

Sometimes you'll get a "ticking" noise as the expanding PVC/DWV lines past thru framing members that are too tight/too small holes or restricted in length....

Does the noise follow the use of HOT water down the drain ?

....as a Test DON'T use the bath faucet.... use a bucket of hot water from the kitchen......Noise ?

Outside cold wall ?

What is the supply line pipe ?

"......measure Once.....cut Twice....

throw that one away and cut a new one...."

BrantJ

01:31PM | 04/06/13
Member Since: 04/06/13
1 lifetime posts
You are correct. The vent pipe, or "stack" is likely the cause of your frustration and Doug Seibert nailed it. I'm betting that when it's very cold outside and you run hot water the noise is louder. I pulled off the baseboard behind my toilet and found the stack to be located in the wall about 16" from the back of the toilet towards the sink using a drywall saw. The sole plate (2"x4" board that runs along the floor) was in contact with the stack pipe. I used a sawzall (carefully - at an angle to avoid cutting the stack) and removed the piece (a "cat's paw" works well to pop out the piece(s)). See picture. I just covered the area with some beadboard behing the toilet. Should've done this years ago - 10 minutes of work. See photo.
Vent%20pop
Click_to_reply_button Inspiration_banner

INSPIRATION GALLERY



Post a reply as Anonymous

Photo must be in JPG, GIF or PNG format and less than 5MB.

Reply_choose_button

Anonymous

Post_new_button or Login_button
Register

Follow_banner_a
Newsletter_icon Google_plus Facebook Twitter Pinterest Youtube Rss_icon
 
webapp2