15A Outlet 20A breaker
No problem with 15amp outlets on 20 breakers with 12 guage wire for residential. If commercial or you are planning to use a 20 amp appliance, then...
No problem with 15amp outlets on 20 breakers with 12 guage wire for residential. If commercial or you are planning to use a 20 amp appliance, then...
1
answers691
Viewslinoleum is a term that was coined in the 1800's. It was and sometimes still is used interchangably for flooring whether it is a vinyl or some oth...
2
answers165
ViewsCould be a number of things. If not dirty evaporator coil or condensor coil, then try dirty air filter. If not then you need a service call for l...
6
answers351
ViewsI haven't but high chlorine levels is very hard on copper pipe. Don't know of a home unit but look at commercial heat exchangers.
4
answers109
ViewsMost stuff is rated to run at 110 to 130 without much trouble. There will always be some voltage flucuations but yours seems a little high. If all...
7
answers335
ViewsA 4 wire cable has the red and green as one pair and yellow and black as the other. One wire of the pair is referred to as the tip and the other w...
1
answers204
ViewsFirst you need to punch holes and/or break up the bottom so water will drain out. I would go ahead and fill it up with sand or whatever. Shouldn'...
1
answers995
ViewsAverage risers are about 7". 7.5" gets a little steep but 6.5" makes a nice height step and especially for older people. Average tread depths are...
3
answers707
ViewsSorry Hollywood, been gone for a while. It isn't a heat pump. I replaced the sequencer and that appears to have fixed it. The sequencer being a ...
9
answers860
ViewsContact someone like servicemaster to see what they recommend.
4
answers736
ViewsHave your a/c checked out. It may be pulling to many amps. Either from a bad compressor or fan motor or the starting capacitor for them went bad....
1
answers290
ViewsI went over tonight with a new thermostat and that didn't fix it. The old one was ok. Switch it to heat and the heat ran all the time. Switched ...
9
answers145
ViewsThanks Juleous. I didn't explain well but the heat/cool switch will shut the a/c off and then switch it to run the furnace non-stop if allowed to ...
9
answers273
ViewsAny idea why a coleman furnace&a/c combo from a 78 model mobile home won't shut off and which part it is that needs replacing? Switching from cool...
9
answers1153
ViewsDon't do it with concrete that way. I'm in the middle of tearing out a concrete porch that rebar into the foundation didn't hold up. It sagged ne...
2
answers601
ViewsDon't use roofing tar. It is too messy and won't take much pressure. Use a silicone caulk.
3
answers215
ViewsIt shouldn't. It happens around here with rain all the time.
1
answers127
ViewsYou can run the wire and boxes with some help. You might look for a good book on it. The hard part is cutting into the wall, installing new work b...
2
answers250
ViewsThree 4 bulb 40 watt flourescent fixtures should do it. Go with 4 fixtures if this is a long narrow space over 30 some feet long. Put one in the ...
2
answers515
ViewsIt is because of the change in temperature and humidity. You need to adjust the freezer and refrigerator settings.
2
answers901