ViewsThe plastic ones will melt just as fast as any other plastic of it's kind, they are constructed a little larger to accommodate better wiring method...
1
answers477
ViewsCall a qualified electrician ...."Electricity is not a hobby"When dealing with the breaker panel special care must be taken, there are live parts i...
1
answers513
ViewsYou can install low voltage and line voltage together you will need a mechanical divider.But I don't recommend your Cat#5 data cable being so clos...
1
answers218
Views"Electricity is not a hobby"You probably have a problem with your neutral buss, but you should really have a qualified electrician look at this.
4
answers738
ViewsIf I were you I would replace the box in the wall with a deeper on and run a dedicated circuit to the refrigerator and put in a single receptacle, ...
1
answers799
Views"Is it due to possible overheating"Absolutely ... the size of the conductors does dictate which box to use do to overheating.Also electricity does ...
1
answers928
ViewsIf your going to do it, do it right.....Broan and Nutone are the best names out there, it's just about all that I put in
2
answers212
ViewsAre there any disadvantages in doing this? None whats so ever ...... I do that all the time when I'm working on a job with either a lazy "rocker" o...
2
answers46
ViewsSplice the red and the black together, this will make your receptacle "constant hot."Then you splice a little piece of wire to the red and black so...
2
answers410
ViewsCall a qualified electrician
1
answers113
ViewsIf you haven't already have this solved just find the two wires that go to the light fixture and connect the new wires of your receptacle to the wi...
1
answers444
ViewsDear Davey B:With electricity assuming something could get someone killed.Please be more explicit. What room is it in, is it a switch or receptacle...
3
answers1001
Viewsif your house wasn't built after 1985 it's a good bet that you don't have wire rated for 90º .....
3
answers464
ViewsDear Shuanm:Here is the article in the 1999 National Electrical Code Book (the latest edition)(personal observation: the indivual contuctor of 90º...
3
answers172
ViewsBut in here Steve we get to weed out the jerks that like to burn crosses.
3
answers401
ViewsDear Steve:If you had an email address I would have sent you a few articles from the 1999 National Electrical Code Book (latest version available. ...
1
answers479
ViewsDear jhami:The application you described sounds like what some of us in the trade call a "feed through", the black and the white wires were already...
3
answers184
ViewsDear Steve:Here are some codes from the “1999 National Electrical Code Book”(1)Spacing. Receptacles shall be installed so that no point along t...
3
answers783
ViewsGeorge can you be more explicit in your description of a "Pigtail"?There are some of us in different parts of the States that use different slang t...
3
answers358
Views