switch loop
You had a switch loop as I suspected. The proper wiring at the receptacle is now to have all the whites connected together and to the silver screws...
You had a switch loop as I suspected. The proper wiring at the receptacle is now to have all the whites connected together and to the silver screws...
8
answers974
ViewsThe green is ground. Connect to bare wire or box if it is metal.
2
answers119
ViewsCould be bad tubes or ballast. If it is an old fixture it could be the starter. Try new tubes first. They are cheapest.
1
answers55
ViewsYou need to find the other end of the cable coming to that jack and adjust the wiring there as well.
2
answers292
ViewsWhen you say 3 wire do you include the ground? If you did then you can't have both the outlet and the fan switched. The switch is currently wired a...
8
answers819
ViewsIf the lights are controlled from more than one location the you have 3 or 4 way switches. If there is only one switch contolling the light then yo...
4
answers926
ViewsSome heat and a roller might allow it to be rolled out to the edge.
2
answers649
ViewsNO you can't use a tandem breaker for this aplication. It only pprovides 2 120 volts circuits. You need 2 full spaces in the panel to get 220 volts.
7
answers861
ViewsIf the wiring is as you describe you can't do it. You said 1 cable form sconce and one from ceiling fixture. If both of those cable only have black...
1
answers128
ViewsWith the fuse off you can remove the wires from the heater and cap the feed wires separately with wire nuts. Leave them in a junction box with a co...
7
answers385
ViewsActually only the bottom one is 6 1/8 to compensate for no tread on patio. the others are still 7 21/32 because a tread goes on both the above and ...
3
answers329
ViewsIt is ok to double up ground wires. It is not OK to double up neutral(white ) wires.
2
answers920
ViewsOK you can get power. You don't have a neutral wire so power is useless with no return path.
5
answers700
ViewsYou need a double 15amp breaker. Since you don't have any empty slots you need to have a sub panel installed. You can't use the existing 15 & 20 am...
7
answers370
ViewsA duplex switch has a common screw for power to both switches. Look a atab connecting two screws. The common side usually has 2 screws close togeth...
2
answers946
ViewsIt is possible that potential buyer will want the fuse box replaced. It is not required as far as I know. If they insist on it as condition of sale...
3
answers381
ViewsYou need to get a voltage testing device and measure if there is still votage on the heater. Then pull the fuses until you find the ones that contr...
7
answers888
ViewsI need more info. Have you run the wires? Can you change how they are run. How are the wire run now? Where does the power wire come in? How are t...
2
answers966
ViewsIf there is only one cable with 3 wires + ground then you can not get power fromthe switch. There is no neutral. All the wires are hot or switched ...
5
answers855
ViewsIf he pulled it out I don't see why the toilet had to be replaced.
4
answers730