Installing Drywall, should I keep the lathe or remove it?
It depends on how the removal of the thickness of lathe will affect the thickness of the new wall. If leaving the lathe and installing drywall make...
It depends on how the removal of the thickness of lathe will affect the thickness of the new wall. If leaving the lathe and installing drywall make...
4
answers617
ViewsIf the breaker is 15 amp is not a problem. Just make sure someone doesn't change it to 20 amp because they think the whole circuit is 12 guage.
1
answers555
ViewsCan you get into the attic. If you can then use a hoo that is bolted up. Drill throught the 2x4 and use a nut and washer above and below and tighte...
6
answers872
ViewsYou can not do this. You have buried a connection inside the wall. This is not allowed. All connections must be in a box that is accessable. You mu...
4
answers274
ViewsIf they used the proper antifreeze there is no danger. Even if they used the wrong stuff just let the water run for a long time (10-15 minutes). I ...
4
answers740
ViewsHe probably did you a big favor. That 3rd wire can be used to power you dishwasher. It is a multiwire circuit. The white neutral is shared between ...
5
answers834
ViewsSounds like a cse of truss uplift.Here is one link, There are many more if you do a google serach for 'truss uplift'. http://www.buildingscience.co...
2
answers921
ViewsI don't think 2 devices can share a chimney. Best to check with your local building department.
4
answers858
ViewsIf the survey company stands behind their work then they would have to bear the costs of moving the fence installed in the wrong place.
3
answers971
ViewsIf you change the outlets to gfci you can change the breaker to a normal breaker. You don;t need to change all the outlets. One outlet can protect ...
4
answers828
ViewsIs it possible you have racoons in your attic? I know a guy who is in animal removal who once told me sometime they urinate in the attic so much pe...
7
answers898
ViewsIt sounds like need a second jack beside the computer with a filter on it. Call your provider and ask them.
8
answers815
ViewsYou should be able to take the 2 wire and connect it to any of the lights and have the new lights work fine. The new lights should all be connected...
3
answers214
ViewsIf the gaps are opening so that you can see the white ceiling behind, try and get a small brush in the gap and paint the ceiling behind black. You ...
2
answers841
ViewsYou have the common wire on the wrong screw. Put back one of the old switches if you can remember how it was installed. Then install one of the new...
4
answers796
ViewsHave you tried pouring some water down the drains. It could be that the traps are just dried out and letting the sewer smell come up.
1
answers270
ViewsI am no sure but if he is working under master plumber then the master needs to be supervising. In either case he still needs the permit which only...
2
answers683
ViewsThey are probably hammer arresters. They prevent the pipes from banging when you turn of the water quickly. If you can you should leave them or rei...
3
answers635
ViewsIf you can find a replacement plug just smash it out with a hammer. They usually breake easily. Find the replacement first.
8
answers768