In reply to "sweating hardwood floors?"
What is the finish on the floor? Unless it is bare wood the water is not coming from in the wood. Is there a cold AC duct under the sweating spots...
What is the finish on the floor? Unless it is bare wood the water is not coming from in the wood. Is there a cold AC duct under the sweating spots...
2
answers195
ViewsThis site has some strange sensoring software. I notice that ****her[far-ther] gets ***ed. seems a bit extreme.
4
answers610
ViewsYou will need to move the wire from the unswtiched attic light fixture to the switched fixture. Will the wire reach the switched fixture? If not th...
2
answers147
Viewshttp://pages.areaguides.com/ubuild/MakingStairs.htm http://www.hammerzone.com/archives/framecarp/technique/stairs/outdoor.htm http://www.what...
1
answers765
ViewsDon't fasten them to the walls. Build a unit that is free standing and sits on the floor.
4
answers101
ViewsFor sanding stainless steel or made of stainless steel?
2
answers446
ViewsIt could be that the switch once operated half of a receptacle. Some one replaced the receptacle and didn't remove the tab. Now the receptacle is u...
3
answers590
ViewsHeat should soften the glue and allow the laminate to be removed. Don't surprised to find the good wood only around the edge. If you do you could...
2
answers1001
ViewsIt depends on your system setup. Most have only a check valve at the bottom of the well. If that is your case the hydrant can go in the line from t...
4
answers575
ViewsWhat wattage bulbs are you using? What is maximum wattage on the sticker on the fixture? Sounds like a heat problem to me. Must also be a moisture ...
1
answers669
ViewsI would not put the sump pump on a GFCI. It could trip without your knowing and then the sump would overflow.
9
answers727
ViewsBelt sander. Skillful use of a sharp plane.
1
answers125
ViewsYOu should imedeatelychange theat 30 amp fuse to a 15. It will add the resale of house only because the buyer will most likely request it or a pr...
1
answers953
ViewsYou are correct it is improperly wired. I don't know what a "15A plug-in outlet breaker from the big box store" is. You should run a new 20 amp #12...
3
answers917
ViewsThe problem comes when the insulation gets cooked from the heat of the new fixture if it isn't already cooked fromthe old fixture. It is usually no...
39
answers996
ViewsWhat country are in. The upper right image I have not seen used in North America. It looks like Autralian. Generally the L shape or D shape is t...
4
answers134
ViewsAfter the proper electrical inspection the local power company comes and installs the meter. Neither the electrician or the contrator install meters.
1
answers832
ViewsTo verfy the squareness of any rectangular opening measure the diagaonals. Measure form bottom left to the top right and from bottom right to top l...
4
answers991
ViewsIf there is still finish on the floor, paint stripper should work. Heat gun also should work.
2
answers549
ViewsIt is probably a switch loop. That means there is no neutral wire in the box. This is very common for switch wiring.
2
answers207