Your very welcome. Before taking plumbing advice on any list it would be a great idea to know if the advice giver is some nut case guessing or a...
Started doing new constuction again,. 50 family homes for middle income
Sewer and drain cleaning equpment
Your very welcome. Before taking plumbing advice on any list it would be a great idea to know if the advice giver is some nut case guessing or a...
10
answers0
ViewsAnother option is the newer types of grinder toilets that can discharge though a pipes of 3/4" ( I never tried it) There is also a normal sewera...
1
answers0
Views"You should have a thermostat on the front of your water heater" In semi civilized areas one would want an Aqua stat on a "water" appliance
7
answers0
ViewsI am a firm believer heating should be hot water or settle for steam and AC should be separate . Scorched air systems (hot air) is possib...
1
answers0
ViewsI have been using the Ram from General for over 35 years and even learned learned how to rebuild them . Amazing drain cleaner for basins,tub,floo...
4
answers0
ViewsWas the installer licensed and did they connect to a vent that goes to the outside air?
1
answers0
ViewsA water heater can last as little the day it was installed such as the defective AO Smith heaters that were manufactured properly or a copper lin...
7
answers0
ViewsHey all - This is so basic it almost hurts to write it Just moved into my first home.....managed to get the pilot lit on the heater but still no ho...
7
answers0
ViewsLarry is 100% correct you should check the spout for part of a flat washer left inside and the new aerator should only be screwwed on hand tight
7
answers0
ViewsThe 1/4 turn stops the valve from freezing in the open position and sometimes having the valve stem fully open causes a slight drip How can ...
10
answers2
ViewsSimple solution Your refill tube entering the over flow tube on the Douglas valve has to much volume (pressure) and causing the flapper to stay...
20
answers0
Views1-The noise you hear is normally excessive velocity (FPS) and under each fixture there should be a globe pattern type of valve. The globe valve w...
4
answers0
ViewsIf possible you may want to consider drainage lines with perforated pipe leading away from the building
3
answers0
ViewsCall a "plumbing" supplier
6
answers0
ViewsIf the pressure is excessive then the velocity (FPS) could cause erosion or if the plumber used a self clean flux or did not ream the copper pri...
17
answers0
ViewsIf the pressure is excessive then the velocity (FPS) could cause erosion or if the plumber used a self clean flux or did not ream the copper pri...
17
answers0
ViewsIs the pressure low in other areas of the home? It could be ferrous metal having the internal diameter reduced from mineral deposits or rust
3
answers0
ViewsMake sure all the valves you closed you opened fully ..If they are gate or globe valves afterr you open them fully back them off a 1/4 Turn so th...
2
answers0
ViewsAnother diverter will be needed (Check out Delta)
1
answers0
ViewsYes of course you can BUT you must make sure the contoller (Aqua stat) is not damaged