Tieger plumbing
Great question,like how much flux to apply prior to soldering. I normally place a bead of putty under the flange squeezing it flat leaving abo...
Started doing new constuction again,. 50 family homes for middle income
Sewer and drain cleaning equpment
Great question,like how much flux to apply prior to soldering. I normally place a bead of putty under the flange squeezing it flat leaving abo...
3
answers816
ViewsYes there is a Chemical called WATER that is amazing in restoring internal piping to a like new condition and restoring full flow. Even in ext...
1
answers493
ViewsIt is a great idea when using any chemicals to try to clear a drain is to have windows open as you only have one set of lungs and many of the chemi...
3
answers266
ViewsHave you considered calling a licensed professional and please be considerate enough to warm them you used chemicals as many are caustic and cause ...
3
answers303
ViewsMost people are lax when it comes to saying "thank you" as they feel the world owes them and many after the problem is solved will never post anyth...
6
answers924
Views1- Ball valve 2- Gate valve 3- Globe angle 4- Globe straight 5- C x C valve (depending on type) 6- IPS (depending on type) 7- co...
1
answers384
ViewsAll piping should have some type of AMTM markings. Also as must I promote copper fro water supply and roof flashing and cast iron for drainage ...
4
answers911
ViewsGas pressure should not be the requirement it is normally sized by volume required for BTU INPUT and developed length of piping. For example in ...
6
answers800
ViewsJames ALL sinks / showers /bathtubs have an AIR GAP On drainage the space between the waste to the drain is called an AIR BREAK AIR GAP wate...
4
answers215
ViewsTry removing the shower head completely then use the diverter and see if that helps. Sometimes sediment has to be flushed out.
6
answers468
ViewsI would open the wall and then expose the piping then have someone open the bib and have a light hammer ready to tap on the pipe once you locate th...
3
answers909
ViewsOh the old Frost proof hose bib caper where where there are no leaks UNTIL someone opens the frost proof faucet and had a split in it as the home ...
3
answers550
ViewsHave you considered a return bend (180 degree fitting) and using NO HUB couplings this way you can disassemble the couplings when you need access t...
3
answers200
ViewsHave you considered raising the height of the vent?
3
answers219
ViewsA thermocouple just maintains a pilot light has nothing to do with a FUSE
1
answers828
ViewsOld joint compound
5
answers634
ViewsIt could be the packing gland (nut) stuffing box etc just needs tightening. Depending on the type and manufacturer
2
answers559
ViewsNormally I try a larger wrench if that doesn't work then I use a chisel cave in the threads remove the plug snake the line and replace with a lea...
5
answers320
ViewsThank you Larry, I just bought another Ford 350 extended body and needed to get signs for it and checked out the internet and found a great guy fro...
3
answers645
ViewsSimple Get a camera with a built in locater so you can see the condition of the piping and the locater will pin point exactly where you want to cu...
3
answers28
Views