Tieger plumbing
Sorry Susan but I doubt if anyone can tell you what could be the problem without going around making sure all the inside valves are open and then t...
Started doing new constuction again,. 50 family homes for middle income
Sewer and drain cleaning equpment
Sorry Susan but I doubt if anyone can tell you what could be the problem without going around making sure all the inside valves are open and then t...
7
answers275
ViewsNo problem Larry
1
answers104
ViewsThey never do Larry, they want a crash course and then when you go into minor details they get confused with facts..Go figure.
5
answers292
ViewsI don't know what code your using but everyone I ever used had an 11/2" tub waste not 11/4 Drainage is by fixture units = 7.48 gallon =1 cubic ...
5
answers527
ViewsIf you have to ask then call a professional as your asking "What tools" not at least giving us any information saying if it is IPS or copper tubing...
1
answers376
ViewsIt could be a partial blockage or a blocked vent line either way you may find it cheaper in the long run to hire a licensed professional. Many,m...
1
answers506
ViewsYour more then welcome
3
answers150
ViewsIf your toilet is seeping from a defective fill valve or tank bulb or flapper this will cause condensation on the out side of the pipping and mold ...
3
answers114
ViewsLarry, do not take it for granted as many installers figure one valve fits all and even reading Google steam radiator valves some state good for...
8
answers230
ViewsCarefully look at the configuration of the valve. Then look at "normal" radiator steam valves angle pattern. Normally steam valves are globe p...
8
answers123
ViewsDepending on the Ph of the water if its ok I use type K copper under ground
1
answers137
ViewsIf the parts are really stripped and the socket tool does not work then you can open the wall a little more and use a basin wrench to remove the nu...
3
answers1000
ViewsThat would depend on the code and piping in general should be protected from coming in direct contact with cement
1
answers676
ViewsThe system is hot water so you better make sure you drain down the system completely before loosening the union Ell or valve and there will be real...
8
answers193
ViewsHi Bill, That is why I make my own heat sink by installing the cold water feed 27" down then bring it up to the heater to prevent stratification of...
3
answers384
ViewsSomeone forgot to install a dielectric fitting by to prevent electrolytic action between ferrous and non ferrous metals thus the mineral deposits ...
3
answers201
ViewsYes I did that several times On demand has no provisions for water to return to the source thus your losing a lot of water was the water that ...
2
answers539
ViewsWhy install a new one if you had paid a plumber to install it in the fist place have him /her come back and make things right NO CHARGE....
10
answers833
ViewsDid you ask for a licensed plumber? Many times I go behind a franchise stumble bum the worst possible non trained person sent out in the field a...
10
answers243
ViewsI personally would have replaced the Douglas valve and in case of Eljer the outlet is china so possibly roughing up the surface and then drying it...
10
answers521
Views