Safely working around service entrance/drop
The best solution for your purposes is to build a temporary service that complies with the standards established by your serving utility as well as...
The best solution for your purposes is to build a temporary service that complies with the standards established by your serving utility as well as...
4
answers308
Viewsquote: JiminCal WroteSNIPYour only real option at this point would be to re-feed that outlet from a grounded main or sub-panel with sheathed elect...
4
answers770
ViewsA couple of important points. Are there any metallic pathways; such as telephone wires, gas line, water pipe, sewer, intercom wiring, alarm system;...
3
answers94
ViewsPlease check the label on the heater! If the label on the heater specifies a circuit size and/or Over Current Protective Device (OCPD) and that la...
7
answers701
ViewsYour conduit can come up the wall right against the house. The conduit should be secured to the wall within three feet of the LB (capped elbow). ...
3
answers374
ViewsBe advised that you are permitted to use rigid metal conduit elbows (Sweeps) in the underground conduit run to avoid the possibility of cutting thr...
5
answers713
Viewsquote: Also, when going overhead do you still have the Neutral and two conductors and use the support wire for the ground? Yes, that is definitel...
5
answers554
Viewsquote: I don't have room on my panel for another 220v circuit. I'd like to make a 220v outlet in the garage, tapping into the same circuit as the...
1
answers544
Viewsquote: tdhorne,Thanks for clarifying that, and the listing of objects in the current path.In an earlier post I had asked if the transformer’s ea...
15
answers285
ViewsI am probably too late in providing this information but you should have run three conductor with ground cable between the switches and the fan out...
6
answers883
ViewsMost panel equipment that is manufactured for the residential market has only one buss bar installed at the factory. If you look you will find tha...
1
answers193
Viewsquote: tdhorne,Thanks Tom. I had been viewing circuit breakers only for their protection against overloads. But they trip also when faults / short...
15
answers287
Viewsquote: I am having the main panel upgraded to 150 amp service. right now it predates 1960 and the electrician strongly recommended to up graded i...
5
answers272
Viewsquote: I bought a copy of the 2002 National Electrical Code (NEC) last evening. I looked up the requirements for bathroom circuits, and now I have...
5
answers270
Viewsquote: Dana1028, Here’s the converse question - If all the equipment grounding conductors are installed properly, but the grounding electrode co...
15
answers5
ViewsYou have an open neutral. Unless you have trouble shooting experience you will need the services of an experienced residential wireman. --Tom
2
answers954
Viewsquote: Yes, I have a grounding wire that is going outside. I am putting either PVC or copper plumbing back in. Any copper plumbing you install sho...
3
answers957
Viewsquote:Member gs99 posted December 01, 2002 11:10 AM Speaking for all the persons who read the forum, I thank all the persons who kindly reply. ...
14
answers669
Viewsquote: I'm planning on directly burying UF to feed a sub panel in a new detached garage I'm building. The cable will exit the house above ground,...
2
answers958
Viewsquote: On a 20-amp circuit, 12 gauge wire is used. Why shouldn't 20-amp devices be used? What's the purpose of the device rating – to assure it ...
14
answers110