thermostat wiring
This site: http://www.high-performance-hvac.com/thermostat-installation/hvac-thermostats/thermostats-installation/thermostat-wiring-and-wire-colo...
This site: http://www.high-performance-hvac.com/thermostat-installation/hvac-thermostats/thermostats-installation/thermostat-wiring-and-wire-colo...
1
answers471
ViewsThe actual wiring involved in this is trivial -- probably a single cable with 3-6 small wires in it. I would never pay an electrician to do someth...
1
answers143
ViewsFor us to be able to "Help!", you need to tell us more information. What are these 'units' you refer to? What voltage are they? How many amps ...
2
answers613
ViewsThe old standby for height for outlets was about 12" from the floor. (It was common to see electricians measuring this by setting their hammer hea...
3
answers463
ViewsBy far, the cheapest alternative is to have them run a pathway (conduit, raceway, etc.) from the breaker box into that room, and leave it empty at ...
5
answers72
ViewsBasically, yes. Things to watch for: - Make sure the wire nuts (that's the name) are of the right size to handle 3 wires. (Yellow or red ...
1
answers857
ViewsAre you sure you are checking the right breaker? You say the "double pole circuit breaker" didn't trip, but it is unlikely that kitchen lights ...
3
answers492
ViewsBill is quite right; this is against code and probably unsafe. Do remove it. But if you could get under the siding to run that extension cord,...
4
answers167
ViewsThe basic procedure for figuring out a problem like this is to get a neon tester and, starting at the breaker box end, trace the wiring along, chec...
2
answers39
ViewsA couple of the critical points are: 14AWG = #14 American Wire Gauge size. This can carry up to 15Amps current. Type SOOW -- The wire type, ...
4
answers80
ViewsYou can simply run a wire from the current location of the stove to the new location. But some qualifications: - this new wire must be at leas...
6
answers109
ViewsIt would help if you would tell us how many wires there are, and what color they are.
1
answers210
Views"I have already installed the lights. The lights are screwed into the ceiling and are covering the old work boxes. In the old work boxes, I have co...
6
answers223
ViewsBefore wiring this up, you should test whether that antique fan motor will actually work at variable speeds via a dimmer. Many motors, even modern...
2
answers331
ViewsThis is a 240V appliance; it's highly unlikely that a standard extension cord would for this. Did you buy a normal extension cord, or was it a spe...
5
answers519
Views"but when the X10 switch was in the wall the red source wire was connected to the blue X10 wire, the red X10 wire was not used" So this means th...
9
answers753
ViewsI think you may have difficulty finding an automobile inverter that can adequately power a 15A 120V table saw. The ones I've see are designed to...
2
answers296
ViewsThe wiring can certainly handle this additional load. As can the breaker. Even with both of these plugged into this circuit, you are probably usi...
2
answers62
Views"The oil will retain heat longer" Yes, but are you sure that you want that? You want it to shed the heat quickly, into the house, so the occupa...
4
answers411
ViewsOne possibility is to look into getting tandem breakers to use in your main panel. These are just thinner breakers, so that a pair of them fits in...
3
answers762
Views