heat pump
The answer is no it won't. But it will cause both stages of electric heat to come on at the same time.(there are 2 or more stages depending on how...
The answer is no it won't. But it will cause both stages of electric heat to come on at the same time.(there are 2 or more stages depending on how...
1
answers675
ViewsThere is always a common wire on any transformer, regardless of white and red. To find common, take your amp- probe, go from each side of the trans...
3
answers829
ViewsDepending on where you live, and the price paid for gas, the average monthly price to burn a pilot light is about $8.00-$12.00. If you want to get...
1
answers997
ViewsAre you sure the exhaust fan does not vent to the outside? If it vents into the floor space, you would be better off not using it at all. Yes, hum...
3
answers131
ViewsPutting the heat runs at floor level is a good practice for a basement living space. This will keep the floor much warmer than having the vents at...
1
answers298
ViewsElectric water heaters have exactly twice the recovery time as gas. That is why they are bigger tanks. They need the extra storage capacity. Gas, ...
2
answers34
ViewsIs the house a single or 2 story? Here are a few things that will help if it has a forced air heating system .1) Identify the pipes that go to the...
4
answers985
ViewsForget about a home ventilation system, that is not the problem. Air that you pay to heat should not be exhausted to the outdoors anyway.Also,any ...
3
answers561
ViewsYou must have it fixed. Without it,the boiler could dry fire and split wide open. That means neglecting a simple repair could end up costing you p...
2
answers178
ViewsIf you don't need to cool the space, the best way to go is with a stand alone electric or baseboard heater. I know what your're thinking, but elec...
1
answers623
ViewsI think bravey is right on. Also, units installed in the attic tend to allow drafts to form at the floor level when the unit is not running. This ...
2
answers688
ViewsThere is nothing inside of a window unit that would fit that description. The compressor does contain oil, but not enough to leak out of the unit ...
1
answers494
ViewsI would ask the local inspector or a good heating contractor for a second opinion on this one. You may get away with not having to go up so high. ...
6
answers251
ViewsYou can use unpainted 28 gauge sheet metal to make a heat shield. Fasten it 1" off of the combustable material in question. This is known as the cl...
1
answers132
ViewsChange the humidifier pad. Also an EAC can produce ozone and have a weird smell if not real clean.
1
answers886
ViewsA Goodman furnace is as good as anything else out there. We have less trouble with them than Carrier. The variable speed blower is nice , but not ...
1
answers456
ViewsWhy would you need to run a chimney up 12 feet above the roof. Is this going to be a metal b-vent or class 1 chimney? If so be ready to collect th...
6
answers495
ViewsIf the boiler is popping the relief valve it means 1) the automatic fill valve is letting too much water into the system 2) the expansion tank nee...
1
answers784
ViewsIf it's an older Carrier furnace you may just need a new thermocouple. If it's a newer model, that is a whole different story. It will have spark ...
2
answers532
ViewsIt may not be possible to add fan/heat combo unit because you might exceed the circuit amps. When you add the heat part , you need more electric ...
1
answers725
Views