Home > Ask a Question > Fix It Forum > iron/sulfur filter backwash!
Login | Register

iron/sulfur filter backwash!


Posted by Gary Slusser on October 18th, 2005 07:12 PM
In reply to iron/sulfur filter backwash! by Unregistered-Bill on October 18th, 2005 07:04 AM [Go to top of thread]

The usual cause is an incomplete rinse as part of the regeneration of the filter; a manganese greensand filter.

The usual causes of that are: a blocked drain line, blocked injector and/or its throat, or an internal leak in the control valve. The best choice is to call the dealer for service. Potassium permangante (the pink) is a poison...

Gary
Quality Water Associates