Posted by Billhart Moderator on October 13th, 2007 01:32 PM
In reply to Venting a microwave through a block wall by Linette1 on October 13th, 2007 10:46 AM [Go to top of thread]

" It would be vented into a crawl space but I could run a hose like you use for a dryer to the crawl space vent. "

A. NEVER VENT ANYTHING INTO A CRAWLSPACE.

B. NEVER USE "HOSE" FOR A COOKTOP VENT. In fact "hose" should not be used for any venting. You can use flexable regidt aluminum piping for a clothes dryer, but only the minimum needed for hookup. A stove vent much be metal piping.

C. DON'T VENT INTO A VENT.
The pipe needs to run through the outside walls to clear air.

Check the specs on the vent to see the max allowable run include any elbows.

To make the holes you can use a masory bit and drill a number of small holes around the diameter of the hole. Then knock out the center. TRy an go between the webs.

Or you can rent a rotary hammer drill and core bit.