breaker
Do you have a way test the voltage? You need to test the voltage at the breaker terminal when the power is out. If there is no voltage then the breaker connection...
Do you have a way test the voltage? You need to test the voltage at the breaker terminal when the power is out. If there is no voltage then the breaker connection...
5
answersI would find the other breaker that is the red wire and if possible tie the two handle together so they both go off at the same time. You may need to move one of ...
4
answersIt depends on how you run your cables. There are at least eight different ways to do it. The method depends on where the power comes in(s1,s2,light), where the fi...
2
answersThis would be the evaporation coil. It's not an electrical issue. There should not be a disposal fee for the coil. If you took it to the scrap dealer you would ge...
2
answersThe panel can't be in the bathroom. The second inspector is correct. This is not an obscrure code. Your electrician should have known this. Your contractor should...
4
answersWith the power turned off open the switch box. If there is only a white a nd ablck wire and both of them are connected to the switch then you CAN NOT do it becaus...
2
answersWhat size bulbs are in the fixtures? What is maximum bulb rating on the fixture? You could be overheating the area around the fixtures.
3
answersDisconnect it at the house, wind it up and tie it to the pole. Or throw it on the ground and call and tell them the wire fell down and you need it repaired.
1
answersThose instructions do not make sense. 120 volts does not and can not use red and black. It must use white and black(or red). Please read and post the instructions...
4
answersWhat's wrong with PVC and what would you use instead.
7
answersThis is normal. A pump does not maintain a constant pressure like city water. It pumps up to a certain pressure and shuts off and waits for the pressure to drop b...
6
answersAt the light connect the fixture to the white and red wires. Put the switch back on the red and black wires.
3
answersExtention cords are for temporay use. mOst uses in the office would not be considered temporary. It also makes it too easy to overload a circuit.
4
answersMaybe it doesn't unplug. It be hard wired without a plug.
2
answersThe receptacle will work just fine with the reverse polarity. However it is unsafe. If the black are on the gold screw then the power cable feeding the receptacle...
6
answersYes you must have a three way at both ends. I am confused as to what you are attempting to do. Are you changing the dimmer or the switch or both? Can you put back...
6
answersA pipe no matter what it is made is gonf to be visble unless you cover it with box or paint it.
2
answersThe TV and VCR are only two prong plugs. It has nothing to do with two prong receptacles at the TV. Is the Cable wire grounded to the Ground in the circuit panel...
4
answersI think I would use a concrete caulking. It is grey like mortar and come in a regular caulking tube.
1
answers