Latest Discussions : Electrical & Lighting

PSUDrew

04:19AM | 02/03/03
Member Since: 01/07/03
6 lifetime posts
Is it required that a garbage disposal be connected to a GFCI outlet?

Thanks, Drew

Geno

07:23AM | 02/03/03
Member Since: 10/02/02
4 lifetime posts
No not required if it meets 210.8A exceptions

Electrical Inspector

10:56AM | 02/04/03
Member Since: 09/27/02
73 lifetime posts
Here ya go Drew.....

quote:
(A) Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (8) shall have ground-fault circuit-interrupter protection for personnel.

quote:
(6) Kitchens — where the receptacles are installed to serve the countertop surfaces

now this thread ASSumes a residential unit in a kitchen ok?

so, below the countertop differs from above

~S