Latest Discussions : Electrical & Lighting

timman5270

04:41PM | 11/19/09
Member Since: 11/18/09
1 lifetime posts
Several heaters in a couple of rooms is not working. There is power to the thermostat. There is power to the load. I have checked the power at the heater and each leg is 120 volts. I changed out a heater to a new one just purchased but still no heat. I am at a loss to figure out what is going on.

Tom O

03:43AM | 11/21/09
Member Since: 09/17/02
476 lifetime posts
If the baseboard heaters are 240 volt, you'll have to verify that 240 volts are available at the heater. Checking each line to ground does not do that, check line to line.


Post a reply as Anonymous

Photo must be in JPG, GIF or PNG format and less than 5MB.

Reply choose button

Anonymous

Post new button or Login button
Register