The Dean of Home Renovation & Repair Advice

COMMUNITY FORUM

Helen21

04:04AM | 02/18/05
Member Since: 02/17/05
6 lifetime posts
Bvplumbing
Our submersible well pump went bad, we replaced it with a 1H Myers pump, we put new wires on the pump, above ground we put in a new bladder tank 40gal, new fittings, plus new pressure switch, we were told in our Myers book, 20/on-40off, we have adjusted the pressure switch, an we can't set it right. We have water , a small stream, but no pressure, I contacted Myers, they couldn't help. How do we set the pressure.

Bonnie

LonnythePlumber

04:24PM | 02/18/05
If you are only getting a small stream of water then this would not be the pressure switches fault. The switch kicks on if the pressure falls below 20 pounds. Sounds like you're not even getting twenty. Are you sure you have water in the well? Do you have the stage wiring hooked correctly? And other inquiries.

Helen21

07:09PM | 02/18/05
Member Since: 02/17/05
6 lifetime posts
Thank you for your response to my pressure switch, and you were right, today my husband checked and we had a pipes in the home that had clogged up, from rusted pipes and other things, we now have a good water flow.

Thankyou

Bonnie

LonnythePlumber

03:54AM | 02/19/05
Bonnie, you and your husband seem to make a good problem solving pair. It must be enjoyable to deal with problems together and be able to resolve them.